Legacy products

Genuine parts from Eltex has been developed according to the same standards through the years which guarantees that all parts offer the same quality, reliability and safety. If you don’t find your part among the legacy products listed below, please contact us by mail info@eltex.se

qtvmini-minismg-2_1000x667_2

QTVmini stop motion system

Central control unit for up to 15 Mini-SMG yarn sensors (8–180 yarns).

Advantages:

  • Self learning.
  • All settings, and the number of yarns in operation, are shown on the display.
  • ANTI-check (detects excessive yarns moving).
  • Relearn button on the front.

Documents

Leaflet

Manual

qtv-montage-c_1000x667_2

QTV stop motion system

Stop motion system for warping creels, creels for winders or yarn preparation machines.
The system consists of QTV central control unit, indication boxes, Mini-SMG yarn sensors, display for number of yarns in operation.

Advantages:

  • Learn mode counts all yarns in operation
  • Statistics
  • ANTI-check (detects excessive yarns moving)

Yarn sensor Mini-SMG

  • 8, 10 or 12 eyelets.
  • 15 mm spacing between the eyelets.
  • Can be fitted at the front (stacked in rows) or along the creel.

Documents

Leaflet
Leaflet QTVmini

Manual
Leaflet QTVmini

Leaflet
Leaflet QTV & MiniSMG

15130-smg

SMG stop motion system for 1800 yarns

SMG stop motion system for 1800 yarns

This system consist of:

  • 15130 central control unit.
  • SMG156 yarn sensors (max. 100).
  • 15778 indication units (optional).

Yarn sensor SMG156

  • 8, 10, 12, 14, 16 or 18 eyelets.
  • Can be fitted at the front (stacked in rows) or along the creel.
  • Each eyelet has an on-off switch.
  • ANTI-check gives a warning if eyelets have been switched off by mistake.

Documents

Leaflet
15130

Manual
15130

Leaflet
SMG156

Instructions
SMG156

54781-e2070-anti-stor-frilagd_1000x667_2

Weft sensor E2070

Features:

  • 4 / 8 / 12 eyelets.
  • Monitors single and up to four weft insertions in the same pick.
  • Detects if excess number of threads are inserted by mistake.
  • Monitors mixed single and double weft insertions.
  • Single-double switch for each pair of eyelets.
  • Current logic output

Documents

Leaflet

16487-e2071_1000x667

Weft sensor E2071

Features:

  • 4 / 8 / 12 eyelets.
  • Monitors single and up to four weft insertions in the same pick.
  • Detects if excess number of threads are inserted by mistake.
  • Monitors mixed single and double weft insertions.
  • No single-double switches.
  • Current logic output.
54595-e2060_1000x667

Weft sensor ANTI

Features:

  • 8 eyelets.
  • Monitors single weft insertions.
  • Detects if an excess number of threads are inserted by mistake.
  • Current logic output.

NOTE! This weft sensor is replaced by the G3w model.

Documents

Leaflet

54081-e2016_1000x667

Weft sensor E2016

Features:

  • 1 / 4 / 8 eyelets.
  • Monitors single weft insertions.
  • Current logic output.

Documents

Leaflet

sa2090-2_1000x667

Weft sensor S2090 / SA2090

Features:

  • 4 or 8 eyelets.
  • Individual outputs for each eyelet.
  • Open collector output.

Documents

Leaflet

16460_1000x667

Weft sensor Chrome, 16460, 16461, 16466, 16467

Features:

  • Single end weft sensor in chrome finish.
  • Sensitivity setting.
  • Open collector output.

Documents

Leaflet

16580-utan-skugga_1000x667

Weft sensor 16564, Chrome

Features:

  • Single end weft sensor in chrome finish.
  • Sensitivity setting.
  • Optocoupler output.

Documents

Leaflet

16475-frilagd_1000x667

Weft sensor 16470-series, Chrome

Features:

  • Single end weft sensor in chrome finish.
  • Available with sensitivity setting.
  • Current logic output.

Documents

Leaflet
16470

Leaflet
16574

28300_1000x667

Control unit 28300

Features:

  • Current logic.
  • ANTI-function detects if too many yarns are inserted simultaneously by mistake.
  • Detects 1/2/3/4 wefts simultaneously depending on weft sensor model.

Documents

Leaflet

Manual

28700-col_1000x667

Control unit 28700

Designed to replace the units 25700 and 26700 when upgrading old units to the current logic system.

Features:

  • Input for weft sensor with current logic output.
  • ANTI-function detects if too many yarns are inserted simultaneously by mistake.
  • Detects 1/2/3/4 wefts simultaneously depending on weft sensor model.

Documents

Leaflet

28420-col_1000x667

Control unit 28420

Features:

  • Current logic.
  • ANTI-function detects if too many yarns are inserted simultaneously by mistake.
  • Detects 1/2/3/4 wefts simultaneously depending on weft sensor model.
  • Weft stop inhibit switch.
  • Europe size board 100×160 mm.

Documents

Leaflet

22000-sned_1000x667

Control unit 22000 for air-jet

Features:

  • Relay and open collector stop output.
  • Synchronisation input for proximity switch (NPN/PNP) or Eltex light switch.
  • Idle pick input.
  • ANTI-function detects if the yarn has reached too far on the receiving side because of weft break or wrong weft length.
  • Open collector weft arrival signal output.
  • Europe size board 100×160 mm.

Documents

Leaflet

projectile-collage_1000x667

Weft Stop Motions for projectile weaving machines

Eltex supplies complete Weft Stop Motions for machines such as Sulzer TW11 and STB weaving machines.

For newer projectile machines there are weft stop motions available as plug-in modules.

Contact Eltex to order, for an offer or for technical support. Please mention the maker and model of your weaving machine. For order please also mention the number of weft yarns (colours), the reed width and if the Stop Motions should be able to detect multiple weft yarns each pick.

There are upgrade versions for TW11 available.

Documents

Spare parts

Manual

Exchange info

Instructions